INSTRUCTION FOR EL-ROPE
Basic Parameter of EL-ROPE:
Diameter: 0.9mm, 1.4mm, 2.2mm, 3.2mm, 5.0mm; Basic color: Blue, Green, Orange, Red, Purple;
Store temperature: - 40 ? -- + 70 ? Store humidity: < 40%
? Example of application: diameter-2.2mm, length-1m EL-rope
* Flectional diameter: >15mm * Pull: < 1kg
* Rotate angel: 30 º *Input voltage: 110v
* Input frequency: 400Hz-5000Hz *Operation temp.: -40 ? - +70 ?
Rated power in different input voltage:
Volt |
400Hz |
1000Hz |
2000Hz |
5000Hz |
90v |
1.35W |
3.5W |
7.05W |
18.2W |
110v |
1.68W |
4.1W |
8.5W |
22.5W |
130v |
2.05W |
5.2W |
10.75W |
26.5W |
Life of working in different frequency: ( 6hours on, and 18hours off/day)
Frequency/110v |
400Hz |
1000Hz |
2000Hz |
5000Hz |
Life |
6K hours |
3.8K hours |
2.0K hours |
1.2K hours |
* The above data is only for reference.
Caution:
1. The life of working depends on the input voltage, frequency and working condition;
2. The brightness will decrease with the working, and up to 30% of original one at the end;
3. Do not expose the EL-rope in the direct sunshine;
4. Do not cut the rope when it is on power;
5. Connect the rope before plugging into power;
6. Do not touch the electrode when it is in power;
7. Guided under the professional electrician when installing and connection;
1.Insulating wrap of the EL-ROPE 2.Electrode of the EL-ROPE (double thin wires) 3.Electrolyte layer of the EL-ROPE 4.Core electrode of the EL-ROPE 5.Welding point 6.Welding point 7.Input source 8.Input source 9.PVC shrink tube (smaller size) 10.PVC shrink tube (larger size) 11.Wrap of power cable |
Operation of connection:
a. Remove the wrap of EL-ROPE (part 1);
b. Take out the electrode (part 2);
c. Scrape off the electrolyte layer (part 3) on the core electrode (part 4), in order to make the electrode naked;
d. Remove the wrap of Power cable (part 7 & 8);
e. Weld the Power Cable separately with the Electrode of EL-ROPE (part 5 & 6);
f. Coat the welding point with shrink tube (part 10);
g. Coat the connection sector with shrink tube (part 9);